Description


Features:
Heating or cooling control
Red and blue dual led display
Independent Dual-way temperature controller
Temperature display resolution 0.1
Directly power output
Application range is like home temperature control, farm, various cold storage, greenhouse, aquarium, etc.
Specifications:
Display Type: Digital
Shell Material: ABS + PCB
Temperature Sensor: NTC 10K
Senor Length: 1m
Temperature Measuring Range: -55 ° C ~ 120 ° C
Resolution: 0.1 ° C
Accuracy: ±1° C
Power Supply: 110-220VAC 50/60Hz, 12V DC , 24V DC(Please choose power supply when ordering)
Relay Contact Capacity: Two Relay Max 10A
Output Type: Direct Output
Size: 72*56*31mm
Packing List:
1 x Temperature Controller
2 x Waterproof Sensor

|
①NO.1 Work Signal  |
②NO.1 Measured Temperature |
â‘¢NO.1 Start Temperature Set |
â‘£NO.1 Stop Temperature Set |
|
⑤NO.2 Work Signal |
⑥NO.2 Measured Temperature |
⑦NO.2 Stop Temperature Set |
â‘§NO.2 Start Temperature Set |
|
⑨Item NO. |
Operation instruction:
A. Set The Starting Temperature:
Press the UPÂ button once to display the starting temperature. Long press the UPÂ button for about 3 seconds,The required temperature can be set by the UPÂ and DOWNÂ buttons.
B. Set Stop Temperature:
Press the DOWN button once to display the stop temperature. Long press the button for about 3 seconds and the stop temperature number flashes. The required temperature can be set by the UPÂ and DOWNÂ buttons.
C.Press UP ①button and Up ② button at the same time to setting mode:
Press UP ①and UP② buttons for 3 seconds at the same time to enter the setting mode, display P0, the first group temperature delay, press UP ② and DOWN ② to adjust, 0~60 minutes, default 0, after adjustment, press UP ① since P1, the second group temperature delay, press UP ② and DOWN ② to adjust, 0~60 minutes, default 0. (P2-P3 has no mode)
                                                                                Menu Instruction
|
Code |
Function |
Set Range |
Default |
|
P0 |
â‘ : Delay start |
0-60 minutes |
0 |
|
P1 |
â‘¡: Delay start |
0-60 minutes |
0 |
|
P2 |
           Has no mode |
/ |
/ |
|
P3 |
Has no mode |
/ |
/ |
D. Reset Factory Settings:
When the power is on, press the DOWN ① and DOWN ② buttons at the same time for 3 seconds. The reading shows 888, and then the controller automatically jumps to the detected temperature.
E. Temperature Correction:
Press UP ① and Down ① at the same times for 3 seconds to display 0.0, and then set the value by pressing the Upâ‘ Â and Downâ‘ Â buttons. Â
Positive Value = Measured Value +Corrected Value( NO.2 temperature correction is the same method, press UP ② and Down ② buttons  )
F. Heating Cooling Method:
Operation Method
|
|

1. 12V/24VDC W1088 can use the transformer or 12V/24V DC Power Supply.
2. W1088 is Direct Output: The output and input voltage are synchronized.
When the temperature controller is working ( the indicator light is on), the output voltage is the same as input voltage;
When the temperature controller is off (the indicator light is off), the output will do not have voltage.